Controlled Power Company introduced Double-conversion UPS. The “Model ES” is offered in 4,500VA to 15,500VA single-phase sizes. Able to provide extended battery backup without the need for additional enclosures, the UPS is available with an internal computer-grade isolation transformer.
From its aesthetically-pleasing innovative design … to its ease of installation and user-friendly operation, the “Model ES” UPS is the right choice to provide conditioned, continuous back-up power to today’s mission critical applications.
This true online, double conversion UPS incorporates a field-proven design, which has a solid track record of protecting mission critical applications and preventing downtime. This translates into trusted performance and reliability.
Features & Benefits
- Extended battery back-up time, without the need for additional cabinetry.
- An internal computer-grade isolation transformer provides electrical noise attenuation and power conditioning.
- Nominal input voltage options from 120 VAC to 600 VAC, with conversion to the exact nominal output voltage needed, even in bypass.
- A secure maintenance bypass system that assures a fully in-sync transfer, and allows maintenance to be performed without shutdown.
- A user-friendly, information-rich color monitor with a high resolution touchscreen display.
- Full network communications, including options for Ethernet TCP/IP, MODBUS TCP/IP, or MODBUS 485.
- Output distribution options where you decide the exact receptacles and/or breakers supplied.
Technical Specs
- Input Voltage: Nominal voltages from 120V to 600V at 60 Hz; 220V to 415V available at 50 Hz
- Input Operating Voltage Range: +12%, - 15% at full load; +12%, -40% at 53% load (without battery usage)
- Input Frequency: 60 Hz (50 Hz available), ± 5% from nominal
- Input Power Factor: > .98 typical
- Input Current Distortion: < 5% THD
- Output Voltage: Nominal voltages include 120V, 208/120V, 240/120V or 240/208/120V at 60 Hz; 120V to 240V available at 50 Hz
- Output Line Voltage Regulation: ± 1.5% from nominal typical
- Output Frequency: ± 0.5% while in battery operation mode
- Overload Rating: 125% for 2 minutes, 150% for 30 seconds
- Voltage Distortion: 3% maximum THD with a linear load
- Battery: Valve-regulated, sealed lead calcium, maintenance-free, and field replaceable
- Internal full-load runtimes from 5 to 70 minutes, with extended runtimes from 1 to 5+ hours
- Operating Temperature: 0°C (32°F) to 40°C (104°F) without derating; optimum battery performance and life at 25°C
- Relative Humidity: 0 to 95% non-condensing
- UL 1778 Listed, C-UL Listed to Canadian National Standard C22.2, No. 107.1 M01
Applications
- I.T. Network Server Rooms
- Small to Medium Data Centers
- Industrial Controls and Automation
- Healthcare I.T.
- Business Continuity Requiring Extended Runtimes
|